STEEL STRUCTURE PROTECTIVE EQUIPMENT

Single-Leaf Steel Protective Air-Tight Door

Features

This type of door offers high shock wave resistance. The door leaf adopts an arch tension plate structure, while the door frame wall and door leaf are in planar contact, ensuring flexible operation and easy maintenance.

Scope of Application

Applicable to personnel shelters and Grade 5/Grade 6 civil air defense projects, including underground malls, hospitals, garages, and warehouses.

Key Design Considerations

· Civil air defense doors can be custom-manufactured to specifications based on actual requirements.

· The door model and type shall be selected in accordance with usage requirements.

· Selection may refer to the technical specifications for civil air defense projects

Construction and Installation Requirements

· Distinguish between the door’s opening directions (inward/outward) and reserve reasonable installation space.

· The steel door frame must be securely fixed, with no tilt in any direction. Measures shall be taken to prevent displacement during concrete pouring.

· Door leaf installation shall commence 28 days after concrete pouring of the door frame.

· The door leaf must be balanced and tightly fitted to the frame to ensure its protective and sealing functions.

Product Specifications

No.Model / ParameterDoor Opening Width (mm)Door Opening Height (mm)Door Leaf Width (mm)Door Leaf Height (mm)Door Leaf Thickness (mm)Remarks
1GFM0716(6)70016009001646112Grade 6 straight-through or single-way type
2GFM0818(6)800180010001846112
3GFM0820(6)800200010002046112
4GFM0825(6)800250010002623116
5GFM0920(6)900200011002046112
6GFM1020(6)1000200012002046112
7GFM1220(6)1200200014002046138
8GFM1320(6)1300200015002046132
9GFM1520(6)1500200017002123132
10GFM1720(6)1700200019002123156
11GFM2020(6)2000200022402240156
12GFM2025(6)2000250023002800176
13GFM0606(5)60060080080060Grade 5 straight-through or single-way type
14GFM0716(5)70016009001646116
15GFM0818(5)800180010001846116
16GFM0820(5)800200010002046116
17GFM0912(5)900120011001246156
18GFM0918(5)900180011001846156
19GFM0920(5)900200011002046156
20GFM1020(5)1000200012002046156
21GFM1118(5)1100180013001846156
22GFM1220(5)1200200014002046156
23GFM1221(5)1200210014002046156
24GFM1320(5)1300200015002046156
25GFM1321(5)1300210015002223156
26GFM1520(5)1500200017002123156
27GFM1521(5)1500210017002223156
28GFM1721(5)1500210017002223156
29GFM2020(5)2000200022402046156
30GFM2021(5)2000210022402146156
31GFM2025(5)2000250022402546156
32GFM0716(4B)70016009001646156Grade 4B straight-through or single-way type
33GFM0820(4B)800200010002046156
34GFM0918(4B)900180011001846156
35GFM0920(4B)900200011002046160
36GFM1020(4B)1000200012002046180
37GFM1320(4B)1300200015002046180
38GFM1520(4B)1500200017002125200
39GFM2020(4B)2000200023002300240