WARTIME VENTILATION EQUIPMENT

Electric & Hand-Cranked Dual-Purpose Fan

Performance & Application

Specially manufactured for underground civil air defense projects, this fan is compatible with Model 300 and Model 500 filter absorbers.

  • For gas-filtering ventilation: Connect with the filter absorber to deliver purified air free of toxic agents.

  • For general ventilation: Connect pipelines to the outdoor atmosphere, providing more than twice the air volume of gas-filtering mode.

It is electrically driven under normal power supply and can be operated manually by hand crank once power is cut off.

Operation Guidelines

The three-phase motor can be started directly. Open the air duct only after the motor reaches the rated speed. Rotate the hand crank to lubricate the main shaft regularly.

Turn the hand crank steadily during manual operation.


Maintenance

This equipment is mainly for national defense readiness. If it will not be used after commissioning, remove the hand crank and store it properly near the fan.

Do not run the motor for a long time or start it frequently when the fan is not connected to pipelines.

Inspect the motor insulation resistance every humid season. If the reading is below 2 MΩ, dry the motor thoroughly before reuse.

The fan shall only rotate in the designated forward direction.


Installation Instructions

Before installation, test the motor insulation with a 500V megohmmeter; the insulation resistance shall be no less than 2 MΩ. Check if the three-phase resistance is balanced, all parts are securely fastened and the fan rotates flexibly. Eliminate looseness or friction issues if found. Fill engine oil up to the midline of the oil sight glass to ensure the lower part of the duplex gear is submerged in oil.

The fan can be suspended to the ceiling of the civil defense structure with two long bolts or mounted on a foundation. The height from the ground to the center of the crank is normally 0.9–1.05 meters. In accordance with ventilation system drawings or professional design layouts, connect the air inlet to gas-filtering ducts and general ventilation ducts, and link the air outlet to a flow meter (or Model FX-1 air flow indicator) and indoor pipelines.The weight of the filter, flow meter, pipelines and valves shall not be imposed on the fan. Do not over-tighten bolts to avoid fan distortion. Ensure no contact or friction between the impeller and stationary components after installation.

The rotation direction of the motor and hand crank must comply with the markings on the product.

Conduct pipeline resistance commissioning after installation, and verify that the air volume meets design requirements in both gas-filtering and general ventilation modes.


Main Technical Parameters

ParameterF270-1F270-2
Air Flow (m³/h)300–700500–1000
Total Pressure (Pa)1117–5681205–568
Shaft Speed (r/min)28002800
Rotation Direction (view from motor end)ClockwiseClockwise
Motor TypeYS7132YS7132
Rated Power (kW)0.750.75
Rated Voltage (V)380380
Rated Current (A)1.651.65
Hand Crank MechanismEnclosed two-stage cylindrical gear drive, gear ratio 1/8 × 1/8. Hand crank speed: 44 r/min, swing radius: 280 mm, connected to the main shaft via an automatic clutch.

External Dimensions

ParameterF270-1F270-2
External Dimensions (L×W×H, mm)821 × 545 × 417830 × 545 × 417
Outlet Size (mm)Φ150Φ200
Weight (excluding oil, kg)3840