Installation Configurations
Vertical and box-type installation
Herringbone installation
Horizontal installation (pipeline type and box type)
LWP Oil Bath Filter Main Technical Parameters
| Model | Dust Removal Efficiency (%) | Condition | 600 m³/h | 800 m³/h | 1000 m³/h | 1200 m³/h | 1400 m³/h | 1600 m³/h | 2000 m³/h | Oil Consumption (g/block) |
|---|---|---|---|---|---|---|---|---|---|---|
| LWP-D | 93~98 | Initial | 2 | 2.8 | 3.7 | 4.8 | 6 | 10 | 200~325 | |
| Final | 3.8 | 5.5 | 7.5 | 9.75 | 12.5 | 15 | 200~325 | |||
| LWP-X | Initial | 1.5 | 2.1 | 2.57 | 3.6 | 4.5 | 6 | 125~200 | ||
| Final | 3 | 4.25 | 5.7 | 7.25 | 8.8 | 10 | 125~200 |
Note: Reinforced impact pressure resistance: 0.05 MPa.
Filter Structure & Dimensions
| Model | Mesh Layers | Corrugation Height (mm) | Corrugation Pitch (mm) | Mesh Specs (Front Half) (mm) | Mesh Specs (Rear Half) (mm) | Length (mm) | Width (mm) | Height (mm) |
|---|---|---|---|---|---|---|---|---|
| D | 18 | 5.5 | 11 | 1.3 / 0.29 | 0.64 / 0.23 | 520 | 520 | 120 |
| X | 12 | 4 | 11 | 1.36 / 0.23 | 0.65 / 0.19 | 520 | 520 | 70 |